Office buildings
Office building leak detection
Tenant suites, a finished floor nobody wants opened during trading hours, and a landlord and a tenant who both need to know whose line it is.
Core, shell and fit-out
The same leak lands on two different people

In an office building the physical leak is straightforward and the ownership question is not. Broadly, the domestic supply in the core, the risers and the line from the meter to the building belong to the building; what was added inside a suite during a tenant improvement usually does not. Which of those you have is decided by the lease, not by us.
So the locate is written to make the lease reading easy rather than to take a side. Three facts do most of that work:
- which side of the demising wall the failed section sits on
- whether the pipe is original shell plumbing or part of a later fit-out — material, routing and workmanship usually make that obvious
- whether it is upstream or downstream of the suite's isolation valve
Handed to a property manager and a tenant at the same time, those three tend to end the discussion in one email instead of three.
Method
Detecting without closing a floor
An occupied building sets the order of operations: everything possible with the building running happens first, and the water-off work is booked into a window.
Walk the building with the engineer first
On a building that has changed hands, the engineer's memory of the valve map and what has been isolated before is frequently the only complete record there is.
Do everything that does not need the water off
Meter readings with the building idle, slab-edge listening, thermal imaging through carpet tile and drywall, moisture mapping — none of it interrupts a tenant.
Rule the exterior out before touching the interior
The frontage landscaping, the parking-lot islands and the buried run from the meter are easier to test than anything inside, and account for much of what reads as a building-wide change.
Book the water-off window with the property manager
One isolated section at a time, agreed in advance so the tenant notice goes out once.
Pressure-test by riser and by suite
Each riser or suite that holds is eliminated, which on a stacked restroom core usually collapses the search to one vertical line and the slab beneath it.
Locate to a point, then agree the opening-up
Nothing above a ceiling grid or under a floor covering is disturbed until the property manager has agreed what gets opened and when.
On site
Why locating matters on a finished floor
Stone, carpet tile, millwork and a painted ceiling grid are slow to match and an exploratory hole in the wrong place is visible to every tenant who walks past it for weeks.
Thermal imaging and acoustic listening read through those surfaces. The point of using them is that the first hole is the last hole.
Where they turn up
The usual suspects in an office building
Stacked restroom cores
Restrooms sit one above another, which puts a single set of supply lines through every floor and into the slab under the ground-floor core. A leak in that slab run is the classic office case: it shows up as consumption, or a damp line at the base of a core wall, long before it shows as water.
The line somebody added mid-lease
Break rooms, coffee points and filtered-water taps get run by whoever did the fit-out. They are usually the newest pipe in the building and they fail at a fitting or a transition between two materials rather than along a run.
The site, not the building
Irrigation on the frontage and the parking islands, the buried supply line from the meter, the hose bib nobody has used since the building changed hands. These move a consumption figure without anybody inside noticing anything.
Carpet tile is a very good disguise
A slab leak under carpet tile often reads as an odour complaint first. By the time a tenant reports damp underfoot the water has been travelling along the underside of the slab for a while, which is why the wet tile is a poor guide to where the pipe is.
The paperwork
The document an asset manager can forward
The reader who matters most is frequently not in the state. A locate that works for them says: the building and floor, the suite, what was isolated, what held, what did not, where the failure is, what it is, and which side of the demising wall it sits on — with photographs of the mark before anything was opened.
The same document works for a tenant conversation, a lease reading and a carrier, which is why it is written once and shared.
How an office building locate gets done
Where we work
Office corridors we work
Downtown, the Camelback corridor, Tempe and the south-east Valley.
Straight answers
What property and asset managers ask
Can you do this without shutting the water off to the whole building?
Yes for most of it. Listening, thermal imaging and moisture mapping happen with the building running and often narrow the leak to one floor; only the pressure test needs a section isolated, in a window you choose.
Our tenant's carpet is wet. Is it our pipe or theirs?
That is decided by where the failed section sits, not where the water shows. We report which side of the demising wall it is on, whether the pipe is shell or later fit-out work, and whether it is upstream or downstream of the suite's isolation valve.
Can the water-off testing be scheduled when the building is quiet?
That is the normal arrangement on an occupied building. We agree the window with the property manager in advance so the tenant notice goes out once, and take one isolated section at a time rather than dropping a whole riser.
Do you cover the sewer stack or the water heater in the core?
No. We work the water side: slab and supply lines, buried site lines, water mains, irrigation, pools and spas. Sewer, drains, gas, heaters and backflow assemblies are your plumbing contractor's work, and we will say plainly if that is what you have.
Tell us which floor, and what has to stay open
A photo of the damp area, the meter or the valve room and a note about the building's quiet window is enough for us to plan around your tenants.